800C Ceramic Topped Heater with NiCr Filament

In vacuum flange-mounted heater

  • 800c Vacuum Flange - Mounted Child page

Drawing showing heater with additional outer heatshield & water cooling option

(M6 Stud, shown below, would not be present for flange mounted heater option)

This design means that:

  • Outer heatshield improves heater uniformity and reduces heat load on chamber
  • Water cooling using Ø6.0mm tube wrap
  • Connection via 4VCR or swagelok fittings.
  • Can be supplied with flexible bellows hoses.
  • Cooling water flow rate 1 ltr/min @ ambient temperature

Features

  • 800C Ceramic top plate temperature (1000C Element temperature)
  • Integrated type K thermocouple and power feedthroughs
  • Ramp rate up to 400C per Minute
  • Can be mounted in any orientation
  • Element head is detachable for in chamber mounting through small ports.
  • Reliable low cost proven design.
  • For use in high vacuum, inert atmosphere and O2 / air.
  • Custom sizes available on request.
  • Can be used as direct replacement for Halogen lamp heaters
  • Additional outer heatshield available as an option.
  • Water cooling of additional outer heatshield available as an option.
Part No

ØA – Hot Zone

ØB – Heater o.d. C – Heater Thickness O.D. cooled shield OPTION Voltage Max Current Max

Power Max

HCBF-NCR-02

52 (2”)

66 25 92 40 10

400

HCBF-NCR-03

78 (3”)

92 25 118 85 15

1275

HCBF-NCR-04

105 (4”)

119 25 145 110 15

1650

HCBF-NCR-05

129 (5”)

143 25 169 170 17

2890

HCBF-NCR-06

156 (6”)

170 25 196 200 20

4000

HCBF-NCR-07

179 (7”) 193 25 219 125 36

4500

HCBF-NCR-08

205 (8”)

219 25 245 150 36

5400

  • This field is for validation purposes and should be left unchanged.
×